- Home
- ยป
- Our Product Range
- »
- Dental X-Ray Units
Dental X-Ray Units
CLAROX VX-30 Portable Dental X Ray Machine
Product Brochure
Brand | Clarox |
Model Name/Number | VX-30 |
Machine Type | Portable (Mobile) |
Power Supply Volts | 220 V |
Technology Type | Digital |
Tube Focal Spot | .4mm |
WeightApprox. 1.1 kg excluding optional configurationsX ray tubeCNT Field emission typeMode of OperationSpotAnode angle12.5°Focal spot0.4mmExposure time set0.01~0.5 set digitalTotal filtration2mm AlSSD110mmClassificationClass IIb
Myray Rxdc Extend Wireless X Ray Unit
Product Brochure
Brand | Myray |
Model Name/Number | RXDC eXTend |
Tube Focal Spot | 0.4 mm (IEC 336) |
Generator | Constant Potential,Microprocessor-Controlled |
Working Frequency | 145 - 230 KHz with Self-Adjustment (Typically 175 KHz) |
Anode Current | 4 / 8 mA |
Total Filtration | 2.0 mm Al @ 70 kV |
Voltage at X-ray Tube | 60,65,70 kV |
Exposure Times | 0.020 - 1.000 Seconds,R'10 and R'20 Scale |
Source-Skin Distance | 20 and 30 cm |
Certification | CE 0051,FDA approved |
Arms Length | 40 cm,60 cm,90 cm |
Max. Arm Extension | 230 cm,From Wall |
Details :
RXDC - Intraoral x-ray unit with eXTend wireless technology
Maximum image quality, minimum dose for the patient.
RXDC - eXTend technology provides always-sharp images, a full configuration range and the exclusive flexibility of wireless technology.
This technology gives sharp images with greater detail and lower exposure times than would be attainable with AC X-ray units, which are characterised by variable emissions.
Moreover, constant-potential design ensures image generation is unaffected by power fluctuations.
RXDC - eXTend technology is reliable for all diagnostic needs and always provides high-definition images by adapting to the sensor type.
Always-sharp images
The focal spot of just 0.4 mm is placed in the tube head in such a way as to obtain a source-to-skin gap of 30 cm (total bulk remaining equal).
In this way RXDC - eXTend technology implements extensive internal collimation of the X-rays and gives an extremely small focal spot, producing ever-sharper images and ever-more precise detail.
Multi Mode :
Automatic parameter modulation ensures the best exposure power/time selection: parameters are automatically determined on the basis of the patients build and the specific region of investigation. With 28 selectable sensitivity levels, sharp images are guaranteed with any sensor.
Minimum X-Ray Dose :
Attention to patient health is meticulous: a high frequency, constant potential generator minimises exposure times and reduces harmful radiation. Where deemed appropriate, the 4 mA mode halves the amount of X-rays. The interchangeable rectangular collimator cone (at 30 cm) further reduces the rradiated body surface area by adapting it to the effective surface area of the sensor.
Sequential Exposure :
No downtimes as a result of tube overheating, not even when repeated use is required.The fast dynamic duty cycle allows, in fact, sequential exposures by keeping tube temperature under constant control on the large hand-held unit display.
Fast installation and wireless control :
The efficiency of wireless technology with maximum simplicity of use.
The wireless controller frees users from the limits posed by on-machine control panels or wall-mounted controls. It is equipped with a button for ultra-fast shooting (fraction of a second) and two simple settings which make it easy to select the most suitable X-ray acquisition programme.
Simple Installation, Versatility, Reliability
The solid extruded aluminium arms are made of high quality materials that ensure strength and durability while reducing the risk of accidental vibration during acquisition.
They are available in lengths of 40 cm, 60 cm and 90 cm and can be pointed in 6 directions to provide maximum adaptability and simplicity of installation.
MyRay RXDC Dental X-Ray Machine
Product Brochure
Brand | Myray |
Model Name/Number | RXDC |
Power Supply Volts | 50/60 Hz,115-120Vac +-10%,230-240Vac +-10% |
Generator | Constant Potential,Microprocessor-Controlled |
Working Frequency | 145-230 KHz (Typically 175 KHz) |
Anode Current | 4 / 8 mA |
Voltage at X-ray Tube | 60 / 65 / 70 kV |
Exposure Times | 0.020 - 1.000 Seconds,R'10 and R'20 Scale |
Source-Skin Distance | 20 and 30 cm |
Max. Arm Extension | 230 cm,From Wall |
Certification | CE 0051,FDA Approved |
Arms Length | 40 cm,60 cm,90 cm |
Details :
RXDC - High frequency intraoral x-ray unit
Highest quality with lowest exposure.
Always-sharp images, versatility and meticulous attention to patient health.
High frequency dc generator for sharp images and lower effective dose
The constant potential high frequency generator (DC) provides sharp images with the very highest level of detail.
Compared to AC systems, they also reduce exposure times and the amount of harmful radiation by containing the dose administered to the patient.
A focal spot of just 0.4 mm - one of the smallest available - ensures images are always sharp and of the highest quality. High definition real-time imaging.
Precision diagnostics Superb image definition: sharp edges and excellent detail.An embedded collimator cone gives a source-to-skin distance of 30 cm.
This increases X-ray parallelism, providing more precise images, lower doses and ensuring greater attention to patient health.
RXDC offers maximum flexibility and optimum X-ray quality whatever the type of sensor connected.
Attention to patient health is meticulous thanks to the constant potential DC generator with adjustable power (from 8 to 4 mA). Moreover, rectangular collimators can be used: these reduce the irradiated body area and thus lower the dose received by the patient.
Optimal Ergonomics
Simple installation, versatility, reliability
Versatile and Adaptable
Wall-mounted with variable positions or in a mobile cart-mounted version (to be shared among multiple workstations), RXDC is extremely versatile and easily adapts to all your working needs.
Technical specifications :
| Technical Data |
Generator | Constant potential, microprocessor-controlled |
Working frequency | 145 - 230 KHz with self-adjustment (typically 175 KHz) |
Focal spot | 0.4 mm (IEC 336) |
Total filtration | 2.0 mm Al @ 70 kV |
Anode current | 4 / 8 mA |
Voltage at X-ray tube | 60 / 65 / 70 kV (*) |
Exposure times | 0.020 – 1.000 seconds, R’10 and R’20 scale |
Source-skin distance | 20 and 30 cm |
Irradiated field | Ø 55 mm and Ø 60 mm round |
Additional collimators | 35 x 45 mm rectangular, 31 x 41 mm and 22 x 35 mm, for sensors size 2 and size 1 |
Power supply | 50/60 Hz, 115-120 V AC ±10% or 230-240 V AC ±10% |
Duty Cycle | Continuous operation with self-adjustment up to 1s/80s total |
Arms (for Standard version only) | Available in 3 lengths: 40 cm – 60 cm – 90 cm |
Max. arm extension | 230 cm, from wall |
Certification | CE 0051, FDA approved |
Versions | Standard (wall mounted) or Mobile (on portable cart) |
MyRay RXDC HyperSphere X-Ray Unit
Product Brochure
Brand | Myray |
Focal Spot | 0.4 mm (IEC 336) |
Generator | Constant Potential,Microprocessor-Controlled |
Power Supply Volts | 50/60 Hz,115-120Vac +-10%,230-240Vac +-10% |
Working Frequency | 145-230 KHz (Typically 175 KHz) |
Anode Current | 4 / 8 mA |
Voltage at X-ray Tube | 60 / 65 / 70 kV |
Exposure Times | 0.020 - 1.000 Seconds,R'10 and R'20 Scale |
Source-Skin Distance | 20 e 30 Cm |
Additional Collimators | 31 x 41 mm and 22 x 35 mm,For Size 2 And Size 1 Sensors |
Total Filtration | 2.0 mm Al @ 70kV |
Arms Length | 40 cm,60 cm,90 cm |
Max. Arm Extension | 230 cm,From Wall |
Certification | CE 0051,FDA Approved |
Details :
RXDC, HyperSphere technology
Innovative design, revolutionary ergonomics, advanced technology. RXDC - HyperSphere technology brings the best of DC X-ray units into your surgery.
- Maximum flexibility
- Precision x-ray imaging
- Innovative ergonomics
- Complete reliability
Hyper Ergonomy
HyperSphere technology gives the RXDC unit full rotation capability.
The tube revolves freely around the joint, allow it to reach practically any position, including the vertical. RXDC - HyperSphere technology also features an automatic touch-sensitive device for simple, efficient locking/release of the X-ray head tube so it can be repositioned effortlessly between one exposure and the next. Ergonomic zones on the sides of the head provide a firm grip for effective positioning.
Simple and Immediate:
The wireless remote controller lets the user control the device (by communicating with the X-ray tube) while enjoying full freedom of movement.
Access to exposure programmes is provided via two simple settings. The large display shows the sequential exposure monitor and the patient exposure dose; moreover, the controller has a wireless X-ray snapshot button. Wireless device control allows fast, easy installation: no fixed control panels are required, thus providing greater freedom when positioning the X-ray unit.
Hyper Performance :
With a tiny focal spot of 0.4 mm (at 30 cm), RXDC - HyperSphere technology produces sharp images under any condition.
The tube head is now even more powerful as it operates at 70 kV, 8 mA. RXDC - HyperSphere technology gives your surgery the precision and quality of cuttingedge know-how.
Minimum Dose :
The constant potential high frequency (DC) generator reduces the most harmful low energy radiation that is characteristic of analogue (AC) generators: current is adjustable (from 8 mA to 4 mA), as are exposure times.
Moreover, the long cone (30 cm) with incorporated rectangular collimator reduces the exposed surface area. This maximises image quality and safeguards patient and worker health.
Multi Mode :
Maximum flexibility to meet your diagnostic needs. Automatic parameter modulation ensures exposure power and time are always selected according to the patient’s build and the specific region of investigation.
Sequenced Exposure :
The dynamic service cycle allows uninterrupted use of the RXDC, as in the case of systematic examinations, and real-time monitoring of tube head temperature on the large wireless controller display.
Complete Equipment Set :
RXDC - HyperSphere technology features a 30 cm cone with a circular and rectangular collimator. The rectangular collimator is ideal for reducing the X-ray dose administered to the patient as it limits the irradiated body area to the effective capture capacity of the sensor.
Siger Portable X-Ray Unit
Product Brochure
Brand | Radion Equipment's |
Model Name/Number | Siray |
Generator Capacity | 2mA |
Machine Type | Portable (Mobile) |
Generator Type | High Frequency |
Tube Type | Stationary Anode |
Power Supply Volts | 220 V |
Power Supply Frequency | 50 Hz |
Peak Kilo Voltage | 70kvP |
Table Type | Canon Toshiba Constant Potential Tubehead |
I Deal In | New Only |
Tube Focal Spot | 0.4 |
The exposure can be adjusted between 0.02-2.00s.
High capacity battery, continuouse exposure for 300 times after full power storage.
Buil in overheat protection procedure, eectively protect the tube.
Several languages are optional for operation interface.
Siger SiRay DC Dental X-Ray Machine
Brand | Siger |
Model Name/Number | SiRay |
Exposure Time | 0.05 - 0.5 sec |
Machine Type | Wall Mounted |
Generator | 100K-200KHZ |
Focal Point | 0.7mm |
Compared to power frequency technology:
- Better image quality.
- Compared to traditional AC generators, it greatly reduces the radiation dose.
- Extend the service life of the X-ray generator.
- The amount of radiation output is not affected by voltage fluctuations.
High quality image
- Advanced high frequency and constant voltage DC generator.
- Canon DC X ray tube.
- Focal spot of 0.7mm delivers sharp images with optimal details.
- The selectable kV values (55kV /60kV / 65kV /70kV) and mA values (4mA / 7mA) provide excellent image for diagnosis and research.